Mating Durability |
500 cycles per EIA-455-21 |
Vibration |
Per MIL-STD-1344, Method 2005, Condition II & VI |
Mechanical Shock |
Per MIL-STD 901C Grade A |
Thermal Shock |
-54°C to +65°C per MIL-STD-1344, method 1003 |
Thermal Cycling |
-62°C to +70°C per MIL-STD-1344, method 1003 |
Corrosion Resistance |
500 hour salt spray MIL-STD-1344, method 1001 |
Ozone Exposure |
Per MIL-STD-1344, method, 1007 |
Humidity |
10 cycles per MIL-STD-1678-method, 4030 |
Fluid Immersion |
Per MIL-STD-1344, method 1016 |
Crush Resistance |
7 tests @ 1250 Newton per MIL-STD-1344, method
2008.1 |
Maintenance Aging |
Per MIL-STD-1344, method, 2002 |
Terminus Retention Force |
22 lbs. min. per MIL-STD-1344, method 2007 |
Insert Retention Axial |
100 PSI min. per MIL-STD-1344, method 2010 |
Cable Pull Out Force |
162 pounds min. per EIA-455-6 |
Cable Sealing Flexing |
Per MIL-STD-1344, method, 2017 |
Impact |
Per MIL-STD-1344, method, 2015 |
Flammability |
Per MIL-STD-1344, method, 1012 |
Operating Temperature |
-54°C to +65°C |
Storage Temperature |
-62°C to +70°C |
Typical Insertion loss |
0.4 dB Nominal multimode |
0.5 dB Nominal singlemode |
Connector Insert |
Aluminum Alloy, Anodized |
Connector, Backshells and Dust Cover |
Aluminum Alloy, CAD Plating
316L Stainless Steel
303 Stainless Steel |
Cable Sealing Strain Relief |
Polyolefin, Self Encapsulating |
|
|